Entering content frame

 Procedure documentation Adding a Standby Instance (Hot Standby) Locate the document in the library structure

With the Database Manager GUI, you can add a standby instance to a Structure linkhot standby system.

Prerequisites

·        See Concepts of the Database System, Structure linkSystem Requirements for a Hot Standby System

·        You have already set up the master instance of the hot standby system.

·        You are connected to the database instance of the hot standby system on the virtual server.

Procedure

In the Database Manager GUI, choose Instance ® Configuration ® Hot Standby.

Choose Next to start each of the required steps.

...

       1.      Choose Add or Remove Standby Instances.

       2.      Choose Add Standby Instance. Make the following entries:

Node

Name of the standby computer

Login Name

Operating system user on the standby computer

Password

Password of the operating system user on the standby computer

Installation

Installation path of the database software on the standby computer

Delay

Delay (in seconds) until the standby instance redoes the changes in the master instance.

       3.      Choose Start.

You have added the standby instance and put it in the STANDBY operational state.

See also:

Setting Up a Master Instance (Hot Standby)

 

Leaving content frame